Page view 38
3 - 5
OMNIScanner User Guide
The Adapter: field will automatically change to
reflect that OMNI
Fiber
is currently attached.
OMNI
Scanner
auto-senses the adapter. If the
adapter is changed, OMNI
Scanner
will automati-
cally adjust the content in the fields Autotest:
and Cable: to reflect the new setup.
Every Project has certain Autotests and cables
assigned already. These associated lists will
appear in the pop-up lists for each item. If the
Autotest or Cable you want to use is not in a pop-up list, open
(Setup) to select the appropriate item.
(See Chapter 4 - Setup: Autotest,
Cable, or Project for further information.)
Running an Autotest for Fiber Optic Cabling
Preparing an Autotest
1. Connect OMNI
Fiber
Main to the near end of the RX/TX fiber pair you are
testing and connect OMNI
Fiber
Remote to the far end. Depending on the
method that was used to obtain the reference, connect your fibers as
follows:
2 JUMPER METHOD AUTOTEST
To run an Autotest when the 2-Jumper Method was used to set the Refer-
ence proceed as follows:
1. Do not disconnect the launch cables from the OMNI
Fiber
.
2. Remove the connector sleeves that connect the two launch cables.
3. Connect the OMNI
Fiber
Main to one end of the duplex link under test,
and the OMNI
Fiber
Remote to the opposite end.
RX
TX
850 nm
1300/1310 nm
RX
TX
850 nm
1300/1310 nm
2 m Launch Cable
2 m Launch Cable
Patch Panel
Wall Plate
Cable under Test
Page view 38