Microtest OMNIScanner2 User's Guide Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 133
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
OMNIScanner User Guide
3 - 6
4. Press .
1 JUMPER METHOD AUTOTEST
To run an Autotest when the 1-Jumper Method was used to set the Refer-
ence proceed as follows:
1. Do not disconnect the black connectors which are attached to the TX port
of the OMNI
Fiber
.
2. Disconnect the black connectors that are attached to the RX ports of the
OMNI
Fiber
.
3. Connect the white connectors to the RX ports on the OMNI
Fiber.
4. Connect the OMNI
Fiber
Main to one end of the duplex link under test
and the OMNI
Fiber
Remote to the opposite end.
5. Press .
3 JUMPER METHOD AUTOTEST
To run an Autotest when the 3-Jumper Method was used to set the Refer-
ence proceed as follows:
1. Do not disconnect the launch cables that are attached to the OMNI
Fiber
.
2. Remove the middle launch cable and the connector sleeves that were
attached to the middle launch cable.
3. Connect the OMNI
Fiber
Main to one end of the duplex link under test
and the OMNI
Fiber
Remote to the opposite end.
RX
TX
850 nm
1300/1310 nm
RX
TX
850 nm
1300/1310 nm
2 m Launch Cable
2 m Launch Cable
Patch Panel
Wall Plate
Cable under Test
Page view 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 132 133

Comments to this Manuals